MOST System
MTL Open System Technologies

MOST Redundant Controller
Redundant Controller
MOST System

HARDWARE
SOFTWARE

½Ã½ºÅÛ¼³¸í
MTL8000 I/O-1
MTL8000 I/O-2

 

 

 

 

 

MOST

Open System Components

For The Industrial Automation Market

 

MTL Open Systems Technologies

MTL Open System Technologies (MOST), MTL's new business unit, is committed to providing the industrial automation market with open hardware and software technology-based system building blocks for use in the most demanding real-time system applications.

MOST Products & Services:

  • Open control components, including rugged controllers, process I/O and control software
  • Training classes on process I/O, control software and fieldbus applications
  • MTL offices worldwide to provide superior customer service wherever you need it
  • Comprehensive literature, including catalogs, posters, highly acclaimed application notes and technical papers 

 

 

 

 

 

 

 

  


MOST

MOST products have been widely used in the process automation market, including:

  • Chemicals and Petrochemicals
  • Oil and Gas Pipeline
  • Power Generation
  • Water and Waste Water
  • Cement
  • Pulp and Paper

 

About MTL Open System Technologies

MTL Open System Technologies (MOST) is committed to providing the industrial automation market with open hardware and software technology-based system building blocks for use in the most demanding real-time applications.

Why Open Systems?
Open systems are becoming increasingly popular in the industrial automation market. Open systems are built from commercially available off the shelf products that conform to well-defined standard specifications. Products that conform to these standards are easily connected to each other, allowing a system to be quickly assembled. Systems built from open components provide different benefits to end users, systems integrators and OEMs.

Best of Breed
Open systems, unlike closed proprietary systems, enable end users to choose a "best of breed" solution for competitive offerings at cost-effective prices. Users are not tied to a single vendor, enabling them to add new products to their system as they emerge on the market. They can be confident that they can incrementally update their system one product at a time, assuring that it never becomes obsolete.

Freedom To Choose
Open systems allow system integrators to choose from many vendors to solve their problems, and to quickly implement systems from well-known open technology. They can readily recruit engineers that already know the open technology, enabling new employees to be immediately productive with minimal training costs. And a vendor that provides open components can be a great partner for a system integrator, since he can be confident that the component vendor will not compete with him in the market.

Faster Implementation with Cost Savings
OEMs can take advantage of the substantial existing engineering investment in open component products to create a world class solution with must less development expense than a home grown system. With open components, OEMs are able to bring a finished system to market in much less time at a much lower cost.


¿µ±¹ MTL»ç¿¡¼­ ¹ßÇ¥ÇÑ MOST ¹× MTL8000 Remote I/O ½Ã½ºÅÛÀº ÀϹÝÁö¿ªÀº ¹°·Ð Zone1, Division 1 À§ÇèÁö¿ª¿¡ Á÷Á¢ ¼³Ä¡ÇÒ ¼ö ÀÖ´Â ¿ø°Ý I/O ½Ã½ºÅÛÀÔ´Ï´Ù.  
MTL»ç´Â 1995³â ÀÌÈÄ Fisher-Rosemount»ç¸¦ ºñ·ÔÇÑ ´ëºÎºÐÀÇ DCS¾÷°è¿¡ OEM ¹æ½ÄÀ¸·Î À̸¦ °ø±ÞÇÏ¿© ¿Ô½À´Ï´Ù. ¿©·¯ºÐµéÀÌ À߾ƽô Delta-V ½Ã½ºÅÛÀÇ I/O°¡ ¹Ù·Î »ó±âÁ¦Ç°ÀÔ´Ï´Ù. µû¶ó¼­ ÇʵåÅ×½ºÆ®¸¦ ÃæºÐÈ÷ ½Ç½ÃÇÑ °ËÁõµÈ Á¦Ç°ÀÔ´Ï´Ù.
2002³â °¡À»¿¡ Ãâ½ÃµÈ PID controller (redundant)¸¦ ÀåÂøÇÑ MOST (
MTL Open System Technologies) ¸¦ ´ÙÀ½¿¡ º¸ÀÔ´Ï´Ù.
MOST
Redundant controller
MTL MOST System »ç¾ç¼­ (pdf file)

MOST System˼
1) PID Controller ÀÌÁßÈ­
2) Communication ÀÌÁßÈ­
3) System Power ÀÌÁßÈ­¸¦ °®Ãá È¿À²ÀûÀ̸鼭µµ ¾ÈÁ¤¼ºÀ» È®º¸ÇÑ Process Industry »ê¾÷¿¡ ÀûÇÕÇÑ Á¦¾î½Ã½ºÅÛÀÔ´Ï´Ù.


±âÁ¸ÀÇ °èÀå¼³°è¿¡ µû¸£¸é, À§ÇèÁö¿ªÀÇ ½ÅÈ£Àü¼ÛÀº ´ÙÀ½±×¸²¿¡¼­ º¸½Ã´Â °Íó·³ ±âÁ¸ÀÇ J.B. Box¿¡¼­ ´Ù½ÉÄÉÀ̺í·Î ¸¶¼£¸µÄ³ºñ´Ö±îÁö ¿¬°áÇÑÈÄ ¹è¸®¾î( IS Barrier)¸¦ °æÀ¯ ÇØ´ç DCS, ¶Ç´Â Á¦¾î½Ã½ºÅÛ¿¡ ¿¬°áÇÕ´Ï´Ù.

±×·¯³ª ½ÅÇü MTL8000 Remote I/O Àåºñ¸¦ »ç¿ëÇÏ´Â °æ¿ì¿¡´Â Zone 1, Div. 1Áö¿ª¿¡´Â Á÷Á¢ ÇØ´ç ¸ðµâÀ» ¼³Ä¡ÇÑ ÈÄ ÀÌÁßÈ­µÈ Åë½Å¼±¸¸ Æ÷¼³ÇÏ¿© ÄÁÆ®·Ñ·ëÀÇ ÇØ´ç Á¦¾î½Ã½ºÅÛ¿¡ Á÷Á¢ ¿¬°áÇÏ½Ã¸é µË´Ï´Ù.
¶ÇÇÑ ±âº»ÀûÀ¸·Î HART pass thru ±â´ÉÀ» °®°í ÀÖÀ¸¹Ç·Î ÀÚ¿ø°ü¸®ÇÁ·Î±×·¥ÀÎ Conerstone, AMS (EPM»çÀÎ °æ¿ì)µîÀÇ ¼ÒÇÁÆ®¿þ¾î¸¸ ¼³Ä¡ÇÏ¸é ¹Ù·Î ÇöÀå°è±â±ºµéÀÇ À̷°ü¸® ¹× ÅëÁ¦°¡ °¡´ÉÇÏ¿© Áý´Ï´Ù.
 

µû¶ó¼­ H/WÀÎ ¹è¸®¾î, ¸¶¼£¸µ·¢, ¹è¼±µéÀÌ ÇÊ¿ä¾ø°Ô µÇ¸ç ÀÌ¿¡µû¸¥ °¢Á¾°ø»ç °¨ÃàÀ¸·ÎÀÎÇÑ ºñ¿ë°¨ÃàÀº ¹°·Ð À¯Áöº¸¼öµµ ¾ÆÁÖ °£ÆíÇÏ°Ô ÇÒ ¼ö ÀÖ´Â ÀåÁ¡ÀÌ ÀÖ½À´Ï´Ù. 8000 Block Diagram

Field junction box IS interface Process I/O enclosure
Multicore cable I/O sub-system Fieldbus cable

 

 

 

8000 - costºñ¿ëÀý°¨ÀÇ °³·«ÀûÀκñ±³´Â ¿· ±×¸²°ú °°½À´Ï´Ù. º¸´Â °Íó·³ H/W, Cable ¹× ¼³Ä¡ºñ¿ëµî¿¡¼­ ȹ±âÀûÀ¸·Î ºñ¿ë°¨ÃàÀÌ ÀϾ´Â °ÍÀ» º¼¼ö ÀÖ½À´Ï´Ù. 

Hardware Cable Installation









 

 


2001³â ÇöÀç MTL8000 Remote I/O¸¦ ¼³Ä¡ÇÒ ¼ö ÀÖ´Â Àå¼Ò´Â ´ÙÀ½±×¸²¿¡¼­ º¸´Â °Íó·³ Zone 1 / Division 1Áö¿ª±îÁöÀÔ´Ï´Ù. (±×¸²¿¡¼­ ÆĶõ»ö±òºÎºÐ) ÀÌ·¸°Ô I/O Àåºñ°¡ ÇöÀå°è±â·ù·Î ºÎÅÍ Á÷Á¢½ÅÈ£¸¦ ¹Þ¾Æ ÄÁÆ®·Ñ·ëÀÇ Á¦¾î½Ã½ºÅÛ±îÁö ¹Ù·Î ¿¬°áÇÒ ¼ö°¡ ÀÖÀ¸¹Ç·Î  ÄÁÆ®·Ñ·ë³»ÀÇ Á¦¾î½Ã½ºÅÛ I/O°¡ ÁÙ¾îµé¾î (ÇöÀåÀ¸·Î ºÐ»ê ¹èÄ¡µÈ¼ÀÀÓ) Á¦¾î½ÇÅ©±â ¹× °¢Á¾ À¯Æ¿¸®Æ¼µµ °¨ÃàµË´Ï´Ù.

 

 


¶ÇÇÑ MTL8000 Remote I/O Àåºñ´Â Ç÷£Æ®ÀÇ °¡È¤ÇÑ È¯°æ¿¡ ¼³Ä¡ÇÒ ¼ö ÀÖµµ·Ï,
1) ¾ÈÀüÁö¿ª, À§ÇèÁö¿ª¿¡ °øÈ÷ ¼³Ä¡ÇÒ ¼ö ÀÖ°í,
2) °ø¾÷±Ô°ÝÀÎÁõÀ» ȹµæÇÏ¿´À¸¸ç (SIL2, Lloyd, KRµî),
3) °¢Á¾ ½º¸¶Æ®Àåºñ¿Í ¿¬°á ¹× Åë½ÅÀÌ °¡´ÉÇÏ°í,
4) Ãæ°Ý°ú Áøµ¿¿¡ °ßµð¸ç,
5) ¿µÇÏ 40µµ¾¾ ~ ¿µ»ó 70µµ¾¾ ÁÖº¯¿Âµµ
6) ºÎ½Äȯ°æÀ» ´ëºñÇÏ¿´À¾´Ï´Ù.
µû¶ó¼­ ÇÁ·Î¼¼½ºÀÇ ¾î´À°÷À̳ª ÇÊ¿äÇÑ°÷¿¡ Á÷Á¢¼³Ä¡ÇÒ ¼ö°¡ ÀÖ½À´Ï´Ù.

 

 

 

                                             MTL Process PLC diagram
 

 

 

               Copyright(c) 2001-2007 TM Solutions inc. All rights reserved


Ƽ¿¥¼Ö·ç¼Ç(ÁÖ) / ¼­¿ï½Ã ±Ýõ±¸ °¡»êµ¿ 426-5 (¿ùµå¸Þ¸£µð¾Óº¥Ã³¼¾Å¸2 ºôµù717È£) / Tel:(02)784-2526 / Fax:(02)784-2547