5700
HART Connection System

5700 HART Multiplex System
»ç¾ç¼­(5700 pdf)

°³º°·çÇÁÀû¿ë½Ã
HIM

H/W Sutdown System
SPART

HART Communicator
475

 

Ç÷£Æ® ÇöÀå¿¡ ¼³Ä¡µÈ °¢Á¾ ÇöÀå°è±â·ùÀÇ ÀÚ»ê°ü¸® (Asset Management, ,Instrument Management ¶Ç´Â Field Instrument Management ) Â÷¿ø¿¡¼­ HART digital Åë½ÅÀ» Àû¿ëÇÏ¿©,  °úÇÐÀûÀÌ°í ¿¹Ãø°¡´ÉÇÑ ÇöÀå°è±â À¯Áöº¸¼ö°ü¸®¸¦ ÇÏ´Â°Ô º¸ÆíÀû ÀÔ´Ï´Ù.
conventional 4-20mA °èÀå½ÅÈ£¶óÀο¡¼­
HART digital signalÀ» ÃßÃâÇϱâ À§ÇÏ¿© Àû¿ëÇÏ´Â°Ô HART Connection System (HART Multiplexer¶ó°íµµ ÇÔ)ÀÔ´Ï´Ù.

±âÁ¸Ç÷£Æ®¿¡ ½±°Ô Ãß°¡·Î Àû¿ëÇÒ ¼ö ÀÖÀ¸¸ç, À̸¦ ¼³Ä¡ÇÔÀ¸·Î½á ÇöÀå°è±â·ÎºÎÅÍ º¸´Ù¸¹Àº Á¤º¸¸¦ ȹµæÇÒ ¼ö ÀÖ¾î, ÇÁ·Î¼¼½º ¿îÀü ¹× »ý»ê¼ºÁ¦°í »Ó¸¸ ¾Æ´Ï¶ó,  Ã¼°èÀûÀÎ À¯Áöº¸¼ö°ü¸®°¡ °¡´É ÇÕ´Ï´Ù.

SIL3  5700 HART Connection SystemÀ» ±¸ÃàÇÏ°Ô µÇ¸é,  Áß¾ÓÁ¦¾î½Ç¿¡¼­ ¿ø°ÝÀ¸·Î ÇöÀå°è±âµéÀÇ ÀÌ·Â(history database), ÇöÀç »óÅ (status), Adjustment, configuration, diagnostic µîÀ» ÇÒ ¼ö ÀÖ°Ô µÇ¸ç,  ÀÚ»ê°ü¸®½Ã½ºÅÛ (Instrument Management System, ¶Ç´Â AMS : Asset Management System) Software ¿Í °°ÀÌ »ç¿ëµÇ¾î
¼Õ½±°Ô ÇöÀå°èÀå°ü·Ã±â±â±ºÀÇ °ü¸®¸¦ ÇÒ ¼ö ÀÖÀ¸¸ç,  freeware (¿¹ PACTware) µµ ³ª¿ÍÀÖ¾î Àû¿ëÇÏ´Â Ç÷£Æ®°¡ ´À´Â Ãß¼¼ÀÔ´Ï´Ù.

SIL3 certified 5700 HART Connection SystemÀº Áß¾ÓÁ¦¾î½Ç¿¡¼­ ÇÁ·Î¼¼½º ÇöÀå¿¡ ¼³Ä¡µÈ HART Åë½Å°¡´ÉÇÑ ½º¸¶Æ® Çʵå°è±â·ù (smart field devices) µé°ú Åë½ÅÀ» ÇÏ¿©Diagnostic, Configuration, Adjustment µîÀ» ¼öÇàÇÒ¼ö ÀÖµµ·Ï ¿¬°áÇØÁÖ´Â HART Multiplexer H/W ÀÔ´Ï´Ù.

±âÁ¸  4-20mA ½Ã½ºÅÛÀÇ system cabinet,  marshalling rack¿¡ HART½ÅÈ£¸¦ ºÐ±âÇÒ ¼ö ÀÖ´Â connection systemÀ» ¼³Ä¡ÇÏ¿©,  DCS ¿îÀü¿¡ ¿µÇâÀ» ÁÖÁö ¾Ê°í,  HART½ÅÈ£¸¸À» ÃßÃâ À̸¦ »óÀ§ ÀÚ»ê°ü¸® ½Ã½ºÅÛÀ¸·Î º¸³»±âÀ§ÇÑ Çϵå¿þ¾î ·Î¼­ ´ÙÀ½¿¡ °³·«ÀûÀÎ ±¸Ãà¹æ¹ý¿¡ ´ëÇÑ ºí·Ïµµ¸¦ º¸ÀÔ´Ï´Ù.

5700 HART blockdiagram

     
 ¢º  256 points/ module, Max 63 modules / network , 16,128 points max/ 5700 mux  networkPC(Conerstone S/W)
      ¢º  SIL3 (Systemic Capability - pending) ,  HART Field device input Revision 5 to 7
      ¢º  Zone 2 installation, Field Loop Operation (ATEX, IECEx)
      ¢º  FDT based software package, DTM devices support
      ¢º  256 Channel modularity ,  3-port Isolation
      ¢º  Compact, Modular ¼³°è·Î À¯¿¬ÇÑ È®À强

5700 HART Multiplexer ¿Í HART digital ½ÅÈ£¸¦ ºÐ±âÇϱâÀ§ÇÑ Connection Board ´Â ÇöÀå¿ä±¸»çÇ׿¡ µû¶ó ÀϹÝÁö¿ª¿ë,  À§ÇèÁö¿ª¿ë ¶Ç´Â È¥Àç ¹æ½ÄÀ¸·Î ¼³Ä¡ÇÒ ¼ö°¡ ÀÖ¾î  Cabinet design ½Ã À¯¿¬¼ºÀ» ¹ßÈÖÇϸç, Terminal Block ¼³Ä¡°ø°£ÀÌ¸é ¼³Ä¡ÇÒ ¼ö°¡ ÀÖ½À´Ï´Ù.
¼³Ä¡¹æ¹ýÀ¸·Î´Â :
1) À§ÇèÁö¿ª ¿¹½Ã
5700 schmatic diagram

2) ÀϹÝÁö¿ª ¿¹½Ã
5700 schmatic diagram safe area

 

 

INSTRUMENT MANAGEMENT¿ë SOFTWARE

 

 

FDT / DTM based software¿Í ȣȯµÇ¸ç,  -DD based software¿ë driver´Â °è¼Ó °³¹ßµÇ°í ÀÖ½À´Ï´Ù.
5700 communication driver



º¸´Ù ÀÚ¼¼ÇÑ ÇùÀÇ°¡ ÇÊ¿äÇϽøé ÀÌ ºÐ¾ß¿¡¼­ ¿À·£±â°£ °æÇèÀ» ½×Àº
 Æ¼¿¥¼Ö·ç¼Ç(ÁÖ)¿Í ÇùÀÇ ÇØ Áֽñ⠹ٶø´Ï´Ù.
ÀüÈ­´Â 02-2025-4280 À̸ç, À̸ÞÀÏÀº
sales@tmsolutions.co.kr ÀÔ´Ï´Ù.
°¨»ç ÇÕ´Ï´Ù.  ¿À´Ãµµ º¸¶÷Âù ÇÏ·ç µÇ½Ê½Ã¿À.

 

 

 

 

 

 »ç¾ç¼­(5700.pdf)

Copyright(c)  TM Solutions inc. All rights reserved